HND400U

No picture available

MCCB h400 3P 50kA 400A TM

Cat ref.:HND400U
prt.
EAN No.:

3250613349448

P.U.:1 prt.
Technical Characteristics
Type of order:Toggle
Type of case:Fixed built-in
Number of poles:3 P
Type of pole:3P3D
Complete device with protection unit:yes
Trip Unit:TM A/A
Integrated earth fault protection:no
Compatible with DIN rail mounting:no
Motor drive integrated:no
Frequency:50/60 Hz
Rated operational voltage Ue:220/690 V
Rated insulation voltage:800 V
Rated impulse withstand voltage:8000 V
With under voltage release:no
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:50 kA
Rated service breaking capacity Ics AC according IEC 60947-2:100 %
Breaking capacity on 1 pole with 230 V NF 60947-2:51 kA
Breaking capacity on 1 pole with 400 V NF 60947-2:9 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:85 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:85 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:50 kA
Rated ultimate short-circuit breaking capacity Icu under 440V AC IEC 60947-2:45 kA
Rated ultimate short-circuit breaking capacity Icu under 690V AC IEC 60947-2:20 kA
Thermal protection nob setting xIN:0,63/0,8/1
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:1
Correction factor of rating current for 4 and 5 devices placed side-by-side:1
Correction factor of rating current for 6 devices placed side-by-side:1
Power loss per pole at In:25 W
Power loss per pole at 0.63*In:9,9 W
Power loss per pole at 0.8*In:16 W
Total power loss under IN:75 W
Total power loss at 0.63*In:29,8 W
Total power loss at 0.8*In:48 W
Tripmode:TM
Time of response when opening:10 ms
Electric endurance in number of cycles:1000
Number of mechanical operations:4000
Tightening torque:22Nm
DIN rail mounting with optional adaptator:no
Connection cross-sect. rigid cable:35 / 240mm²
Connection cross-sect. flexible conductor:35 / 240mm²
Connection:Front connection
Type of connection:Terminal
Magnetic protection nob setting xIN:6/8/10/12
Setting type In or Ith:IN
Range of the magnetic adjustment:2400/2800/3200/3600/4000/4400/4800 A
Motor drive optional:yes
Category of use:A
Standard text:IEC 60947-2
European directive WEEE:concerned
Protection index IP:IP4X
Altitude:2000 m
Storage temperature:-35 to 70 °C
Air humidity protection:for all climates
  • HND400U
    No picture available
Customer who viewed this item also viewed
HHD400U MCCB h400 3P 25kA 400A TM
MCCB h400 3P 25kA 400A TM
HHA100Z MCCB h3 x160 TM 3x100A 25kA
MCCB h3 x160 TM 3x100A 25kA
HHA040Z MCCB h3 x160 TM 3x40A 25kA
MCCB h3 x160 TM 3x40A 25kA
HND630H MCCB h630 3P 50kA 630A LSI
MCCB h630 3P 50kA 630A LSI
HHA125Z MCCB X160 3P 25kA 125A
MCCB X160 3P 25kA 125A
SBN390 3P 100A Switch
3P 100A Switch
SBN340 3P 40A Switch
3P 40A Switch
NCN320A MCB 3P 10kA C-20A 3M
MCB 3P 10kA C-20A 3M
NCN132A MCB 1P 10kA C-32A 1M
MCB 1P 10kA C-32A 1M
HHA018Z MCCB X160 1P 25kA 20A
MCCB X160 1P 25kA 20A
CD441J RCCB 4P 40A 30mA AC
RCCB 4P 40A 30mA AC
CD426J RCCB 4P 25A 30mA AC
RCCB 4P 25A 30mA AC
AD190 RCBO 1M 1P 10kA C-32A 30mA AC
RCBO 1M 1P 10kA C-32A 30mA AC