HNA161Z
No picture available
MCCB h3 x160 TM 4x160A 40kA
Cat ref.: | HNA161Z |
EAN No.: | 3250613149741 |
P.U.: | 1 prt. |
Number of protected poles: | 4 |
Number of poles: | 4 P |
Type of pole: | 4P4D |
Trip Unit: | TM F/F |
Compatible with DIN rail mounting: | no |
Motor drive integrated: | no |
Frequency: | 50/60 Hz |
Rated operational voltage Ue: | 220/415 V |
Rated insulation voltage: | 690 V |
Rated impulse withstand voltage: | 8000 V |
With under voltage release: | no |
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2: | 40 kA |
Rated service breaking capacity Ics under 220V AC according IEC 60947-2: | 40 kA |
Rated service breaking capacity Ics under 230V AC according IEC 60947-2: | 40 kA |
Rated service breaking capacity Ics under 240V AC according IEC 60947-2: | 40 kA |
Rated service breaking capacity Ics under 380V AC according IEC 60947-2: | 20 kA |
Rated service breaking capacity Ics under 400V AC according IEC 60947-2: | 20 kA |
Rated service breaking capacity Ics under 415V AC according IEC 60947-2: | 20 kA |
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2: | 85 kA |
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2: | 85 kA |
Rated ultimate short-circuit breaking capacity Icu under 380V AC IEC 60947-2: | 40 kA |
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2: | 40 kA |
Thermal protection nob setting xIN: | 1 |
Range of the thermal adjustment: | 160 A |
Rating current 10°C according to IEC 60947-2: | 187,2 A |
Rating current 150°C according to IEC 60947-2: | 184 A |
Rating current 20°C according to IEC 60947-2: | 180,7 A |
Rating current 25°C according to IEC 60947-2: | 177,4 A |
Rating current 30°C according to IEC 60947-2: | 174,1 A |
Rating current 35°C according to IEC 60947-2: | 170,7 A |
Rating current 40°C according to IEC 60947-2: | 167,2 A |
Rating current 45°C according to IEC 60947-2: | 163,6 A |
Rating current 50°C according to IEC 60947-2: | 160 A |
Rating current 55°C according to IEC 60947-2: | 156,2 A |
Rating current 60°C according to IEC 60947-2: | 152,4 A |
Rating current 65°C according to IEC 60947-2: | 148,5 A |
Rating current 70°C according to IEC 60947-2: | 144,4 A |
Power loss per pole at In: | 14,6 W |
Total power loss under IN: | 43,8 W |
Electric endurance in number of cycles: | 1000 |
Number of mechanical operations: | 4000 |
Depth of installed product: | 68 mm |
Height of installed product: | 130 mm |
Width of installed product: | 100 mm |
Critical distance switching emission/earthed part bottom: | 40 mm |
Critical distance switching emission/earthed part left: | 50 mm |
Critical distance switching emission/earthed part right: | 50 mm |
Critical distance switching emission/earthed part top: | 40 mm |
Critical distance switching emission/insulated plate: | 30 mm |
Critical distance switching emission/live part: | 50 mm |
Type of connection: | with screw |
Range of the magnetic adjustment: | 1600 A |
Can be accessorized: | yes |
Standard text: | IEC 60947-2 |
European directive WEEE: | concerned |
Protection index IP: | IP4X |
Degree of pollution according to IEC 60664 / IEC 60947-2: | 3 |
Altitude: | 2000 m |
Temperature of calibration: | 50 °C |
- HNA161ZNo picture available
Data is subject to errors and technical modifications.