NCN132A

NCN132A MCB 1P 10kA C-32A 1M

NCN132A
NCN132A MCB 1P 10kA C-32A 1M
NCN132A MCB 1P 10kA C-32A 1M

MCB 1P 10kA C-32A 1M

Cat ref.:NCN132A
prt.
EAN No.:

3250614615559

P.U.:12 prt.
Technical Characteristics
Neutral position:without neutral
Number of protected poles:1
Number of poles:1 P
Type of pole:1 P
Curve:C
Bottom connection alignement for modular devices:Aligned terminal
Top connection alignement for modular devices:Aligned terminal
Type of supply voltage:AC
Rated operational voltage Ue:240/415 V
Minimum threshold voltage (Ue min):12 V
Rated insulation voltage:500 V
Max operating voltage:440 V
Rated impulse withstand voltage:6000 V
Rated short circuit breaking capacity Icn under 230V AC according IEC60898-1:10 kA
Rated short circuit breaking capacity Icn under 240V AC according IEC 60898-1:10 kA
Rated service breaking capacity Ics AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 220V AC according IEC 60947-2:7,5 kA
Rated service breaking capacity Ics under 230V AC according IEC 60947-2:7,5 kA
Rated service breaking capacity Ics under 240V AC according IEC 60947-2:7,5 kA
Rated service breaking capacity Ics under 220V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 230V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 240V AC according IEC 60898-1:7,5 kA
Rated ultimate short-circuit breaking capacity Icu under 220V AC IEC 60947-2:15 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:15 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:15 kA
Magnetic regulating currrent at 40° C:5/10 In
min/maxi threshold value of the DC magnetic operation:7/15 In
min/maxi threshold value of the AC thermal operation:1,13/1,45 In
min/maxi threshold value of the DC thermal operation:1,13/1,45 In
Rating current -15°C:38,25 A
Rating current -20°C:38,88 A
Rating current 0°C:36,28 A
Rating current 10°C:34,91 A
Rating current -10°C:37,6 A
Rating current 25°C:32,75 A
Rating current -25°C:39,5 A
Rating current 30°C:32 A
Rating current 35°C:31,23 A
Rating current 40°C:30,44 A
Rating current 45°C:29,63 A
Rating current 5°C:35,61 A
Rating current -5°C:36,95 A
Rating current 50°C:28,79 A
Rating current 55°C:27,93 A
Rating current 60°C:27,04 A
Rating current 65°C:26,13 A
Rating current 70°C:25,18 A
Rating current 0°C according to IEC 60947-2:40,33 A
Rating current 10°C according to IEC 60947-2:38,81 A
Rating current -10°C according to IEC 60947-2:41,8 A
Rating current 150°C according to IEC 60947-2:38,02 A
Rating current -15°C according to IEC 60947-2:42,51 A
Rating current 20°C according to IEC 60947-2:37,22 A
Rating current -20°C according to IEC 60947-2:43,21 A
Rating current 25°C according to IEC 60947-2:36,4 A
Rating current -25°C according to IEC 60947-2:43,9 A
Rating current 30°C according to IEC 60947-2:35,57 A
Rating current 35°C according to IEC 60947-2:34,71 A
Rating current 40°C according to IEC 60947-2:33,83 A
Rating current 45°C according to IEC 60947-2:32,93 A
Rating current 5°C according to IEC 60947-2:39,57 A
Rating current -5°C according to IEC 60947-2:41,07 A
Rating current 50°C according to IEC 60947-2:32 A
Rating current 55°C according to IEC 60947-2:31,04 A
Rating current 60°C according to IEC 60947-2:30,06 A
Rating current 65°C according to IEC 60947-2:29,04 A
Rating current 70°C according to IEC 60947-2:27,98 A
Correction factor of magnetic tripping with 100 Hz:1,1
Correction factor of magnetic tripping with 200 Hz:1,2
Correction factor of magnetic tripping with 400 Hz:1,5
Correction factor of magnetic tripping with 60 Hz:1,1
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:0,95
Correction factor of rating current for 4 and 5 devices placed side-by-side:0,9
Correction factor of rating current for 6 devices placed side-by-side:0,85
Power loss per pole at In:3,65 W
Maximum power loss per pole according to the product standard:6 W
Total power loss under IN:3,65 W
Electric endurance in number of cycles:4000
Number of mechanical operations:20000
Depth of installed product:70 mm
Height of installed product:83 mm
Width of installed product:17,5 mm
Type of top connection for modular devices:with screw
Tightening torque:2,8Nm
Type of bottom rail clip for modular devices:plastic
Type of top rail clip for modular devices:NA
Type of Bottom Connection for modular devices:BIconnect
Bottom removability for modular devices:yes
Top removability for modular devices:yes
Suitable for flush-mounting:yes
Upstream cage clamp delivery status:opened
Downstream cage clamp delivery status:opened
Connection cross-section at output with screw, for flexible conductor:1/25 mm²
Connection cross-section of the access with screws, with flexible conductor:1/25 mm²
Connection cross-section at output with screw, for massive conductor:1/35 mm²
Connection cross-section for rigid conductor, upstream terminals with screws:1/35 mm²
Can be accessorized:yes
Standard text:EN 60898-1, AS/NZS 60898-1
European directive WEEE:concerned
Protection index IP:IP20
Degree of pollution according to IEC 60664 / IEC 60947-2:2
Class of energy limitation I²t:3
Altitude:2000 m
Storage temperature:-25 to 80 °C
Temperature of calibration:30 °C
  • NCN132A
    NCN132A MCB 1P 10kA C-32A 1M
    NCN132A
  • NCN132A
    NCN132A MCB 1P 10kA C-32A 1M
    NCN132A
  • NCN132A MCB 1P 10kA C-32A 1M
  • NCN132A MCB 1P 10kA C-32A 1M
Customer who viewed this item also viewed
NCN110A MCB 1P 10kA/15kA C-10A 1M
MCB 1P 10kA/15kA C-10A 1M
AD190 RCBO 1M 1P 10kA C-32A 30mA AC
RCBO 1M 1P 10kA C-32A 30mA AC
SBN390 3P 100A Switch
3P 100A Switch
SBN340 3P 40A Switch
3P 40A Switch
NCN320A MCB 3P 10kA C-20A 3M
MCB 3P 10kA C-20A 3M
MCCB h400 3P 50kA 400A TM
HHA125Z MCCB X160 3P 25kA 125A
MCCB X160 3P 25kA 125A
HHA100Z MCCB h3 x160 TM 3x100A 25kA
MCCB h3 x160 TM 3x100A 25kA
HHA040Z MCCB h3 x160 TM 3x40A 25kA
MCCB h3 x160 TM 3x40A 25kA
HHA018Z MCCB X160 1P 25kA 20A
MCCB X160 1P 25kA 20A
CD441J RCCB 4P 40A 30mA AC
RCCB 4P 40A 30mA AC
CD426J RCCB 4P 25A 30mA AC
RCCB 4P 25A 30mA AC
AD185 RCBO 1M 1P 10kA C-10A 30mA AC
RCBO 1M 1P 10kA C-10A 30mA AC
Data is subject to errors and technical modifications.